Posts

Syngas Analyzer

Image
Syngas Analyzer: Vasthi Instruments Gasification is a technological process that can convert any carbonaceous (organic) raw material such as coal into fuel gas, also known as synthesis gas in short syngas. Generally a high temperature/pressure vessel where oxygen or air and steam are directly contacted with the coal or other feedstocks like coal, biomass, and some waste material causing a series of chemical reactions to occur that convert the feed to electricity, syngas and ash/slag (mineral residues). How Vasthi syngas analyzer works: Vasthi uses heated probe to collect the sample from the sample line, it will maintain constant temperature and removes the dust and mist from the sample gas. This gas sample passes through electrically heated tube to cooler. It will remove the vapour content and cools the gas sample to 5ᵒC dew point range and this sample gas goes through the filter that eliminates the dust particle remaining and finally sensor senses and gives the e...

Dew Point Meter

Image
Portable Dew Point Meter : Portable Dew Point Meter is designed to measure the performance of drying systems for compressed air, nitrogen,transformer and other compressed gases. This Portable Dew Point analyzer Model is ideal for monitoring medical, commercial and industrial applications including plastics resin dryers, breathing air, pneumatic tools, instrument air, and spraying/coating applications. You can use this Dew Point analyzer continuously up to 90 hours without low battery indication. http://www.vasthi.com/portable-dew-point-meter/ Dew Point Meter analyzer measures dew point by utilizing microprocessor circuitry to convert sensor signal by the use of psychometric equations. Assembled in a rugged hand held IP‐ 65 protected plastic enclosure and equipped with quick disconnect tubing couplings and an internal sensor manifold.Dew point meter used for compressed air and nitrogen gasses. ←

ONLINE VOC ANALYZER

Image
ONLINE VOC NMHC ANALYZER WITH FID-GC TECHNOLOGY: Vasthi Instruments Online VOC Analyser with FID-GC technology for monitoring Methane and Non methane components in different industries. Vasthi Instruments has manufacturing and R&D facility in India for VOC analysers with FID-GC technology. Vasthi -NMHC VOCs online analyzer is a high temperature version of Vasthi-3000-NMHC. There is specialized heating box inside for analytic gas path. By adopting air bath heating method, it can make chromatographic column and gas paths before of after it in high temperature condition. During detection and sampling of high-temp. VOCs for specific pollutants (such as diesel engine emission of shipping vessel, flue gas emission of petrochemical refinery and etc.), http://www.vasthi.com/online-voc-analsyer/ it offers heat tracing for sampling gas path/analysis gas path which will effectively prevent gas of high boiling point and low steam pressure from attaching to the walls of ga...

Ultraviolet Differential Optical Absorption Spectroscopy Gas Analyzer(UVDOAS)

Image
UVDOAS Gas Analyzer:   Vasthi Instruments   UV DOAS Gas analyser for Sox, Nox and other emission monitoring as per CPCB Guidelines. The module uses the long optical path UV DOAS technology. Its optical technology platform consists of light source, gas chamber, optical and spectroscopic (including diaphragm, holographic grating, linear array detector) and other optical components. The same gas has different absorption in different spectral band, the absorption of different gases in the same spectral band has superposition effect. Through the analysis of continuous spectrum, a variety of gas can be measured at the same time. The holographic grating is used for light splitting of light absorbed by gas to be measured, sensor array is used to convert the spectral optical signals into electrical signals, after obtaining the continuous absorption spectra of medium, and a variety of gas can be measured at the same time. http://www.vasthi.com/uvdoas-gas-analyzer/  

Continuous PM10 & PM 2.5 Monitoring Analyzer

Image
Continuous PM10 & PM 2.5 Monitoring Analyzer: Vasthi Instruments VDPM – 6000, Real – Time Portable Beta Attenuation Mass Monitor, continuously measures the mass concentration of ambient particulate matter collected onto glass filter tape with time resolu-tion of one-minute. The VDPM-6000 employs an in-line sampling geometry in which the attenuation of beta rays across filter media is measured and particulate matter is sampled simultaneously. This allows ambient sampling to occur for virtually 60 minutes each hour. It also allows for beta ray measurements to be made for virtually the entire hour thereby improving sensitivity and time resolution. http://www.vasthi.com/continuous-pm10-pm-2-5-monitoring-analyzer/ VDPM – 6000 employs a unique “in-situ” sampling technique where the beta measurement is kept at a near fixed temperature above ambient conditions, thereby minimizing measuremen...

Ambient Carbon Monoxide Analyzer

Image
Ambient Carbon Monoxide Analyzer  Carbon monoxide Analyzer uses non-dispersive infrared gas filter correlation technology, combined with the most advanced microprocessor technology provides accurate, reliable Co ppm level detected, suitable for application of atmospheric monitoring requirements. Working principle non-dispersive infrared gas Analyzer carbon monoxide filter correlation technology. CO molecules on the specific laws of infrared optical absorption in accordance with Beer-Lambert. Comparison of infrared energy in the sample and reference gas absorption http://www.vasthi.com/ambient-carbon-monoxide-analyzer/ . Concentrations of CO can be obtained. Full control over all the functions of this instrument at the same time, can also provide important operating parameters of online instruction. During the measurement, real-time automatic compensation of the temperature and pressure changes.

AMBIENT IOXIDES OF NITROGEN ANALYZER

Image
Vasthi Instruments Nitric oxide Analyzer using chemiluminescence detection principle, combined with the most advanced microprocessor technology provides accurate and reliable low NOx detection of ppb-ppm level, suitable for atmospheric monitoring and dilution of pollution online monitor application. Nitric oxide work is the basic principle of chemiluminescence http://www.vasthi.com/ambient-oxides-of-nitrogen-analyzer/ Analyzer. 03 and NO reaction after the absorption of chemical energy, is inspired to the excited state, and excited when you return to the ground state, and release energy in the form of photons. Chemiluminescence intensity is proportional to the concentration of gas can be quantitative measurement of material.Download Catalog Download Specification Sheet